Papakaukau Kiekie-māmā Puʻukū Centrifuge

ʻO ka wehewehe pōkole:

Hoʻohana ʻia ʻo TGL series desktop high-speed refrigerated centrifuge no ka bacteria, protein, nucleic acid extraction, subcellular component separation, clinical test sample processing, kūpono no ka lāʻau lapaʻau, ola ʻepekema, biopharmaceutical, ʻepekema mahiʻai, palekana kaiapuni a me nā ʻāpana noiʻi ʻepekema ʻē aʻe, nā kulanui.


Huahana Huahana

Huahana Huahana

Nā mea nui

m1627625017

Pono ʻenehana
ʻO ka hoʻoheheʻe ʻana o ka pahū-pahū a pau me ka hao nui, ka lua centrifugal kila kila.
ʻO ka hoʻokele kaʻa kaʻa kaʻa ʻokoʻa DC ʻole mālama ʻole, ka hana maʻemaʻe a mālie.

Microcomputer processor pololei ka mana, hōʻike kikohoʻe, hana maʻalahi, helu maʻalahi o ka ikaika centrifugal RCF waiwai, ka wikiwiki a me ka ikaika centrifugal hiki ke hoʻololi ʻia me kekahi i hoʻokahi kī.

Hoʻohana ia i ka fluorine-free compressor unit, double-cycle refrigeration, ikaika ka wela a me ka hiki ke hoʻololi i ke anuanu, ka mana kūpono o ka mahana, ka hoʻomaha wikiwiki a ʻaʻohe haumia kaiapuni.
ʻO 10-wikiwiki a me ka hoʻokele deceleration, E kūʻai i 10 mau pūʻulu o nā papahana maʻamau.

E hoʻohenehene i ka laka puka uila, maʻalahi e hoʻohana, me ka hana wehe puka pilikia.
Hoʻohana ʻia ka lima cone puna e hoʻopili ai i ka rotor a me ke kumu nui.He maʻalahi ka rotor a me ka wikiwiki e hoʻokomo a wehe, ʻaʻole kuhikuhi, palekana a hilinaʻi.

ʻO ka laka o ka puka, overspeed, wela a me ka pale ʻana i ka pale ʻakomi, Ke kuhi hewa ʻana iā ia iho.
Ua hala ISO 9001, ISO 13485, CE, TUV palapala.

Māmā Māmā 16000r/min Max RCF 20600*g
Nui Nui 6*100ml Kaulana Mahana -20℃~40℃
Ka manawa 1~9h/59min walaʻau ≤60dBA
Anana 610*570*370mm Kaumaha Upena 82KG
Holo pololei ± 20r/min Lako ikehu AC220/100V,50/60HZ,10A
Pono ka wela ±1 ℃

TGL16 Nā Rotor Kaulike

Rotors No. ʻAno rotor ʻO ka māmā kiʻekiʻe (r/min) Volume(ml) ʻO RCF Max(×g)
No30401 Rotor kihi kihi 16000r/min 12×1.5/2ml 17940×g
No30402 Rotor kihi kihi 14000r/min 40×0.5ml 19970×g
No30403 Rotor kihi kihi 15000r/min 24×1.5/2ml 20600×g
No30404 Rotor kihi kihi 13500r/min 30×1.5/2ml 19340×g
No30405 Rotor kihi kihi 15000r/min 16×5ml 19350×g
No30406 Rotor kihi kihi 14000r/min 12×7ml 16370×g
No30407 Rotor kihi kihi 10000r/min 12×15ml 11840×g
No30408 Rotor kihi kihi 12000r/min 12×10ml 14510×g
No30409 Rotor kihi kihi 12000r/min 8×20ml 14510×g
No30410 Rotor kihi kihi 12000r/min 6×30ml 14000×g
No30411 Rotor kihi kihi 11000r/min 6×50ml 13480×g
No30412 Rotor kihi kihi 10000r/min 6×70ml 10810×g
No30413 Rotor kihi kihi 10000r/min 4×100ml 10310×g
No30414 Rotor kihi kihi 10000r/min 6×100ml 11380×g
No30415 Rotor kihi kihi 14000r/min 6×10ml 16460×g
No30416 Rotor kihi kihi 15000r/min 30×0.5ml 18510×g
No30639 Rotor kihi kihi 5000r/min 24×15ml 3080×g
No30627 Rotor kihi kihi 5000r/min 30×15ml 3830×g
No30437 ʻO ka hoʻolele rotor 12000r/min 24 pcs Capillary 15800×g
No30444 Rotor kihi kihi 11000r/min 48×1.5/2ml 12840×g
No30980 ʻO ka hoʻolele rotor 13000r/min 4×5ml 14960×g
No30935 Rotor kū pololei 14000r/min 16×5ml 12660×g
No30676 Microplate rotor 4000r/min 2×3×48 Pono 2300×g
No306 Rotor kihi kihi 14000r/min 4×8PCR(0.2ml) 12070×g
No306 Rotor kihi kihi 13000r/min 6×8PCR(0.2ml) 16080×g
No306 Rotor kihi kihi 14000r/min 8×8PCR(0.2ml) 13390×g
No306 Rotor kihi kihi 13000r/min 12×8PCR(0.2ml) 17220×g

  • Mua:
  • Aʻe: